September 25, 2017 (Updated amongst Series four Watches, Sep 13, 2018)
The San Francisco Chronicle published an article today, "New Apple Watch reignites concerns over radiation" (Catherine Ho, September 25, 2017).
Since the novel Apple Watch tin move operate similar a jail cellphone phone, only about world wellness researchers together with medical experts accept raised concerns most the potential wellness risks from exposure to the radiations emitted past times this device.
"There is no definitive information from federal wellness regulators showing a straight link betwixt jail cellphone band radiations — also known equally radio frequency radiations — together with wellness problems inwards humans. But recent query indicates that exposure to jail cellphone band radiations is the probable motility of malignant growths inwards the brains together with hearts of manly individual rats, together with tin move motility neurological harm inwards rats born to mothers that were exposed to the radiations during pregnancy."
The article mentions my successful lawsuit against the California Department of Public Health. It also discusses the cell band radiations together with cancer study conducted past times the National Toxicology Program.
“ 'That’s going to upwards the exposure together with likely growth the conduct chances to the user over the long term,' said Joel Moskowitz, a researcher at UC Berkeley’s School of Public Health. 'I don’t recollect there’s anyone who tin move tell definitively this is going to wound the user. But many scientists would tell nosotros don’t accept plenty information to claim these devices are safe.' ”
"We accept prove that levels of radiations far weaker than those of a jail cellphone band tin move live on damaging to human sperm equally good equally to the progeny produced past times animals that are meaning together with exposed to this throughout their pregnancy.”Devra Davis, Environmental Health TrustNeither Apple nor the CTIA would comment on the story.
The article is available at http://bit.ly/aplwatch3.
--
Specific Absorption Rates (SARs) for the Apple Watch (Series 3)
Before reading what Apple reports (below), I advise you lot read the next posts on my website which beak over why the SAR is non a reliable mensurate of the potential wellness risks from using a wireless device on or close your body.
What's Wrong amongst Cell Phone Radiation Exposure Limits? (SAR)
Children are to a greater extent than exposed to jail cellphone band radio-frequency radiations than adults
Children are to a greater extent than exposed to jail cellphone band radio-frequency radiations than adults
AirPods: Are Apple’s New Wireless Earbuds Safe? (Blood-brain barrier effects)
Apple Watch Series four RF Exposure Information
Apple Watch has been tested together with meets applicable limits for radio frequency (RF) exposure.
Specific Absorption Rate (SAR) refers to the charge per unit of measurement at which the torso absorbs RF energy. SAR limits depend on whether Apple Watch is used against the caput or on the wrist. In the U.S, together with only about countries, the SAR bound is 1.6 watts per kilogram averaged over 1 gram of tissue for operate against the caput together with 4.0 watts per kilogram averaged over 10 grams of tissue for operate on the wrist. In other countries, the SAR bound is 2.0 watts per kilogram averaged over 10 grams of tissue for operate against the caput together with 4.0 watts per kilogram averaged over 10 grams of tissue for operate on the wrist.
The SAR distribution at the exposed side of the head or torso was measured at a distance no greater than 5.0 mm from the inner surface of the shell.
Although this device has been tested to create upwards one's heed SAR inwards each band of operation, non all bands are available inwards all areas. Bands are theme on your service provider’s wireless networks.
Devices that are designed to live on worn on the wrist may operate inwards speaker vogue for phonation communication, with the device worn on the wrist together with positioned adjacent to the mouth. When next-to-mouth SAR evaluation is required, the device is positioned at 10 mm from a flat phantom filled with caput tissue-equivalent medium. The device is evaluated amongst wrist bands strapped together to stand upwards for normal operate conditions.
Devices that are designed or intended for operate on extremities or mainly operated in extremity exclusively exposure conditions; i.e., hands, wrists, feet together with ankles, may involve extremity SAR evaluation. When the device also operates inwards unopen proximity to the user’s body, SAR compliance for the torso is also required. When extremity SAR evaluation is required, the device is evaluated amongst the dorsum of the device touching the apartment phantom, which is filled amongst torso tissue-equivalent medium. The device was evaluated amongst Sport wristband unstrapped and touching the phantom. For Metal Loop and Metal Links wristbands, the device was evaluated with wristbands strapped together with the distance betwixt wristbands together with the phantom was minimized to stand upwards for the spacing created past times actual operate condition.
Although this device has been tested to create upwards one's heed SAR inwards each band of operation, non all bands are available inwards all areas. Bands are theme on your service provider’s wireless networks.
The highest tested SAR values for each Series four model of the Apple Watch were equally follows:
Model A1975
head (over 1 gram):
cellular = 0.25 W/kg
Wi-Fi = 0.14 W/kg
Bluetooth = 0.11 W/kg
simultaneous = 0.39 W/kg
extremity (over 10 grams):
cellular = 0.34 W/kg
Wi-Fi = 0.11 W/kg
Bluetooth = <0.1 W/kg
simultaneous = 0.40 W/kg
Model A1976
head (over 1 gram):
cellular = 0.25 W/kg
Wi-Fi = <0.1 W/kg
Bluetooth = 0.10 W/kg
simultaneous = 0.35 W/kg
extremity (over 10 grams):
cellular = 0.27 W/kg
Wi-Fi = <0.1 W/kg
Bluetooth = <0.1 W/kg
simultaneous = 0.32 W/kg
head (over 1 gram):
cellular = 0.25 W/kg
Wi-Fi = <0.1 W/kg
Bluetooth = 0.10 W/kg
simultaneous = 0.35 W/kg
extremity (over 10 grams):
cellular = 0.27 W/kg
Wi-Fi = <0.1 W/kg
Bluetooth = <0.1 W/kg
simultaneous = 0.32 W/kg
Model A1977
head (over 1 gram):
cellular = 0.37 W/kg
Wi-Fi = 0.13 W/kg
Bluetooth = <0.1 W/kg
simultaneous = 0.50 W/kg
extremity (over 10 grams):
cellular = 0.26 W/kg
Wi-Fi = <0.1 W/kg
Bluetooth = <0.1 W/kg
simultaneous = 0.32 W/kg
cellular = 0.37 W/kg
Wi-Fi = 0.13 W/kg
Bluetooth = <0.1 W/kg
simultaneous = 0.50 W/kg
extremity (over 10 grams):
cellular = 0.26 W/kg
Wi-Fi = <0.1 W/kg
Bluetooth = <0.1 W/kg
simultaneous = 0.32 W/kg
head (over 1 gram):
cellular = No cellular
Wi-Fi = 0.17 W/kg
Bluetooth = 0.13 W/kg
simultaneous = Not applicable
extremity (over 10 grams):
cellular = No cellular
Wi-Fi = 0.10 W/kg
Bluetooth = <0.1 W/kg
simultaneous = Not applicable
cellular = No cellular
Wi-Fi = 0.17 W/kg
Bluetooth = 0.13 W/kg
simultaneous = Not applicable
extremity (over 10 grams):
cellular = No cellular
Wi-Fi = 0.10 W/kg
Bluetooth = <0.1 W/kg
simultaneous = Not applicable
Model A2007
head (over 1 gram):
cellular = 0.37 W/kg
Wi-Fi = 0.13 W/kg
Bluetooth = <0.1 W/kg
simultaneous = 0.50 W/kg
extremity (over 10 grams):
cellular = 0.26 W/kg
Wi-Fi = <0.1 W/kg
Bluetooth = <0.1 W/kg
simultaneous = 0.32 W/kg
cellular = 0.37 W/kg
Wi-Fi = 0.13 W/kg
Bluetooth = <0.1 W/kg
simultaneous = 0.50 W/kg
extremity (over 10 grams):
cellular = 0.26 W/kg
Wi-Fi = <0.1 W/kg
Bluetooth = <0.1 W/kg
simultaneous = 0.32 W/kg
Model A2008
head (over 1 gram):
cellular = 0.36 W/kg
Wi-Fi = 0.14 W/kg
Bluetooth = 0.10 W/kg
simultaneous = 0.50 W/kg
extremity (over 10 grams):
cellular = 0.31 W/kg
Wi-Fi = 0.11 W/kg
Bluetooth = <0.1 W/kg
simultaneous = 0.42 W/kg
cellular = 0.36 W/kg
Wi-Fi = 0.14 W/kg
Bluetooth = 0.10 W/kg
simultaneous = 0.50 W/kg
extremity (over 10 grams):
cellular = 0.31 W/kg
Wi-Fi = 0.11 W/kg
Bluetooth = <0.1 W/kg
simultaneous = 0.42 W/kg
Apple Watch Series 3 RF Exposure Information
Apple has posted information on its website most the Specific Absorption Rate or SAR for the Series iii Apple Watches.
Apple Watch has been tested together with meets applicable limits for radio frequency (RF) exposure.
Specific Absorption Rate (SAR) refers to the charge per unit of measurement at which the torso absorbs RF energy. SAR limits depend on whether Apple Watch is used against the caput or on the wrist. In only about countries, the SAR bound is 1.6 watts per kilogram averaged over 1 gram of tissue for operate against the caput together with 4.0 watts per kilogram averaged over 10 grams of tissue for operate on the wrist. In other countries, the SAR bound is 2.0 watts per kilogram averaged over 10 grams of tissue for operate against the caput together with 4.0 watts per kilogram averaged over 10 grams of tissue for operate on the wrist.
During testing, Apple Watch radios are gear upwards to their highest transmission levels together with placed inwards positions that copy operate against the head, amongst 10 mm separation, together with on the wrist, amongst no separation. When placing Apple Watch close your face, proceed at to the lowest degree 10 mm of separation to ensure exposure levels stay at or below the as-tested levels.
Although this device has been tested to create upwards one's heed SAR inwards each band of operation, non all bands are available inwards all areas. Bands are theme on your service provider’s wireless networks.
The highest tested SAR values were equally follows:
GPS together with Cellular Models:
Model A1860
1.6 W/kg (over 1 g) SAR Limit
Head: 0.53
Head: 0.53
4.0 W/kg (over 10 g) SAR Limit
Wrist: 0.18
Wrist: 0.18
Model A1889
1.6 W/kg (over 1 g) SAR Limit
Head: 0.29
Head: 0.29
4.0 W/kg (over 10 g) SAR Limit
Wrist: 0.15
Wrist: 0.15
Model A1890
1.6 W/kg (over 1 g) SAR Limit
Head: 0.16
Head: 0.16
4.0 W/kg (over 10 g) SAR Limit
Wrist: 0.14
Wrist: 0.14
Model A1861
1.6 W/kg (over 1 g) SAR Limit
Head: 0.52
Head: 0.52
4.0 W/kg (over 10 g) SAR Limit
Wrist: 0.34
Wrist: 0.34
Model A1891
1.6 W/kg (over 1 g) SAR Limit
Head: 0.35
Head: 0.35
4.0 W/kg (over 10 g) SAR Limit
Wrist: 0.18
Wrist: 0.18
Model A1892
1.6 W/kg (over 1 g) SAR Limit
Head: 0.25
Head: 0.25
4.0 W/kg (over 10 g) SAR Limit
Wrist: 0.14
Wrist: 0.14
GPS –only Models:
Model A1858
1.6 W/kg (over 1 g) SAR Limit
Head: 0.17
Head: 0.17
4.0 W/kg (over 10 g) SAR Limit
Wrist: 0.034
Wrist: 0.034
Model A1859
1.6 W/kg (over 1 g) SAR Limit
Head: 0.11
Head: 0.11
4.0 W/kg (over 10 g) SAR Limit
Wrist: 0.023
Wrist: 0.023
New Apple Tree Spotter Reignites Concerns Over Jail Cellphone Call Radiation